Local load carrying capacity

Symbol -
Unit -
Attribute-ID gta_switch_bevel_mesh_local_capacity
Numeric ID 12091
Value Type PMBoolean

Calculation of the local load capacity for all bevel gear and hypoid stages based on FVA Research Project 223 and additional follow-up projects.

The calculation is performed using the FVA program BECAL (in German), based on the results of the local stress calculation.

Many local load capacity checks can be performed if operating conditions such as oil and material information, roughness, temperatures, and lubrication conditions are specified. This results in the safety values for certain types of gear damage and required intermediate values:

Local load capacity