Running-in allowance for f_pe
Symbol
y
p
Unit
µm
Attribute-ID
iso_6336_2006_amount_of_running_in_y_p
Numeric ID
14214
Value Type
PMTechValue
Running-in amount to reduce the transverse base pitch deviation.