Depending on the bulk temperature calculation method, the bulk temperature or friction coefficient can also be specified. Alternatively, three calculation approaches are available:
- For calculation according to KLEIN [FVA519] using the WECH approach, the bulk temperature is determined based on the power loss according to WECH (FVA 519 I).
- For calculation according to HOMBAUER [FVA516], the bulk temperature is calculated based on an iterative determination of the power loss (FVA 516 I).
- For calculation according to KLEIN [FVA 519], the bulk temperature is approximated as a function of the pinion torque.