| Symbol | θM |
|---|---|
| Unit | °C |
| Attribute-ID | iso_6336_20_21_bulk_temperature |
| Numeric ID | 19565 |
| Value Type | PMTechValue |
The bulk temperature ΘM is the temperature of the tooth surfaces immediately before they come into contact. The bulk temperature is established by the thermal balance of the gear unit.
An approximate value for the bulk temperature consists of the sum of the oil temperature Θoil and a part of a mean value derived from the flash temperature Θflaint over the path of contact according to method C (21).
| ϑM-C or ΘM | bulk temperature |
| ϑoil or Θoil | oil temperature |
| C1 | empirically determined factor according to test results as mean value of C1=0.7 |
| Xmp | contact factor xmp=(1+np)/2 with np number of meshing gears |
| ϑflaint or Θflaint | flash temperature |
| XS | lubrication factor (1 for dip lubrication, 1.2 for spray lubrication, 0.2 for gears submerged in oil) |
The following options are available:
(ISO6336-21:2022 clause 6.1.6 formula 21-22)