Weighting factor

Symbol C1
Unit -
Attribute-ID iso_6336_20_21_weighting_factor_c1_combo
Numeric ID 19583
Value Type PMString

The weighting factor C1 is used in the calculation of the bulk temperature ΘM. It is an empirically determined factor derived from test results and averaged out to 0.7.

The following options are available:

  1. User specified
    Direct numerical input

  2. Acc. to ISO 6336 part 20/21

(ISO6336-21:2022 clause 6.1.6 formula 21)