Weighting factor

Symbol C2
Unit -
Attribute-ID iso_6336_20_21_weighting_factor_c2_combo
Numeric ID 19584
Value Type PMString

The weighting factor C2 is used in the calculation of the integral temperature Θint. It was determined empirically from test results and resulted in 1.5.

The following options are available:

  1. User specified
    Direct numerical input

  2. Acc. to ISO 6336 part 20/21

(ISO6336-21:2022 clause 6.1.4 formula 18)