| Symbol | θM |
|---|---|
| Unit | °C |
| Attribute-ID | iso_10300_20_bulk_temperature |
| Numeric ID | 200753 |
| Value Type | PMTechValue |
The bulk temperature θM is determined according to method B (ISO 10300:20). Influencing variables are the oil temperature θOil, the tip relief factor XCA, the lubrication factor XS, the load dependent power losses PVZP (determined according to method C), the immersion depth ed, and basic geometry variables (face width b1,2 and mean pitch diameter dm1,2 of pinion and wheel). The direction of rotation factor is set to D = 0.3 for this calculation (recommended value for hypoid and bevel gears).