Structure factor

Symbol XW
Unit -
Attribute-ID iso_10300_20_structure_factor
Numeric ID 200773
Value Type PMDouble

The structure factor XW is used to describe the influence of the microstructure on the scuffing load capacity according to ISO 10300 part 20; see the following table:

Material XW
Through-hardened steel 1.0
Phosphate-coated steel* 1.25
Copper-coated steel* 1.5
Bath or gas-nitrided steel 1.5
Hardened carburized steel, with lower than average austenite content 1.15
Hardened carburized steel, with average austenite content (10 % to 20 %) 1.0
Hardened carburized steel, with greater than average austenite content 0.85
Austenite steel (stainless steel) 0.45

* Values for phosphate- and copper-coated steels are valid for non run-in surfaces.