Height of mesh point over deepest immersion point of stage

Symbol hc
Unit mm
Attribute-ID height of pitch point over deepest immersion
Numeric ID 3441
Value Type PMTechValue

The height of the pitch point above the deepest point of immersion at the stage is determined automatically as long as the shafts are aligned parallel to the oil level. If the shaft is at an angle to the oil level, an error occur in the calculation and a manual specification is requested.

Both gears are immersed
One gear is immersed
  Oil is sprayed directly into the mesh Oil is not sprayed directly into the mesh
hc Height of mesh point over deepest immersion point of stage
emax Tooth tip depth at the design point