Face load factor for scuffing

Symbol KBβ
Unit -
Attribute-ID iso_6336_20_21_face_load_factor
Numeric ID 5399
Value Type PMDouble

The face load factor for scuffing KBβ can be set equal to the face load factor KHβ from ISO6336 part 1. In the scuffing load capacity calculation, KBβ is used to calculate the transverse unit load wBt and thus takes into account the force distribution over the face width.

The following options are available:

  1. User specified
    Direct numerical input

  2. Acc. to ISO 6336 part 1