| Symbol | C2 |
|---|---|
| Unit | - |
| Attribute-ID | iso_6336_20_21_weighting_factor_c2 |
| Numeric ID | 7649 |
| Value Type | PMDouble |
The weighting factor C2 is used in the calculation of the integral temperature Θint. It was determined empirically from test results and resulted in 1.5.
The following options are available:
(ISO6336-21:2022 clause 6.1.4 formula 18)