| Symbol | KH |
|---|---|
| Unit | - |
| Attribute-ID | agma2101c95 load distribution factor K_H |
| Numeric ID | 978 |
| Value Type | PMDouble |
The load distribution factor KH considers an uneven distribution of the load along the contact lines.
The following influencing factors should be considered:
The load distribution factor KH can be defined as follows:
The calculation via the specification of individual factors uses the following formula:
KH = 1.0 + KHmc * (KHpf * KHpm + KHma * KHe)
where
| KHmc | lead correction factor |
| KHpf | pinion proportion factor |
| KHpm | pinion proportion modifier |
| KHma | mesh alignment factor |
| KHe | mesh alignment correction factor |