Calculation acc. to FVA 240/II with input parameters from FVA 411 (optional)

Symbol -
Unit -
Attribute-ID control_parameter_calc_acc_fva240
Numeric ID 9863
Value Type PMBoolean

In the flank fracture calculation according to FVA 240/II, the principal shear stress is set in relation to the core hardness of the gearing. The following methods are available for calculating the principal shear stress:

A simple calculation method for estimating the risk of flank fracture for bevel gears was developed in FVA Project 240/II, based on extensive investigations of this type of damage on gears in both test and in practice (R. Annast: Flank load capacity and running behavior of hard-finished bevel gears, damage from flank fracture. FVA publication 690, Frankfurt, 2003).

The key parameter is the ratio of principal shear stress to core hardness: τH12 / HKH [N/mm²/HV].

Design recommendation: τH12HKH0,55 Nmm2 HV

If the limit value is exceeded, the risk of flank fracture is high. The ratio τH12 / HKH can be influenced by the hardness profile and the core hardness at half of the height of the flank, as well as by the load and the curvature ratios.