Maximum bulk temperature

Symbol θT
Unit °C
Attribute-ID max_mass_temperature_agma_2003
Numeric ID 9875
Value Type PMTechValue

The maximum mass temperature θT reduces the flank and root strength at values above 120 °C. This is considered via the temperature factor Kθ > 1.0 for θT > 120°C, which reduces the permissible flank and root stress.

If a maximum mass temperature θT below 0 °C is to be expected, the material properties must be adjusted in accordance with AGMA 2003.

Input options: