Relative circle difference

Symbol -
Unit -
Attribute-ID stplus_configuration_related_circle_difference
Numeric ID 9500
Value Type PMDouble

The relative circle difference is preset to 1000 and can be varied between 250 and 5000.

The numerical value specified represents the divisor which the normal module is divided by in order to reach the minimum permitted deviation.

Δ= mn / input value