| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | agma2101c95 application conditions Y_N |
| Numeric ID | 1132 |
| Value Type | PMInteger |
According to AGMA 2101 C95 (D04), the flank and tooth root safeties are determined simultaneously using 2 methods with different service life factors ZN and YN:
User specification of the service life factors
Here, the safety is calculated using the specified service life factors. The required operating time is not taken into account. The default value of 1.0 can be used in accordance with Chapter 10 in AGMA 2010-C95 (D04), where specific experience and satisfactory performance has been demonstrated by successful use of established service factors.
Service life factors according to diagrams
Here, the safety is determined using the service life factors from Fig. 17 or 18 in AGMA 2101 C95 (D04) based on the required operating time and the type of application (critical or general application).