| Symbol | ZXY |
|---|---|
| Unit | - |
| Attribute-ID | calculation_point_virtual_cylindrical_gear_pair_iso_10300 |
| Numeric ID | 11467 |
| Value Type | PMInteger |
The calculation point on the path of contact of the virtual cylindrical gear (points A, B, C, M [center], D, or E) can be selected for determination of the pitting load capacity. The standard method for determining the pitting load capacity is the original calculation method according to ISO 10300 (2014) (calculation point M-B).