| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | stplus_agma_2101_switch_z_n_y_n_greater_10_power_10 |
| Numeric ID | 13038 |
| Value Type | PMBoolean |
With this switch, the values for ZN and YN are extended beyond 1010 load cycles (see Figures 17 and 18 from AGMA 2101-D04).
"These figures stop at 1010 due to insufficient data at the time the standard was developed. Application beyond this point must be reviewed." (AGMA 2101-D04, Section 17.2)