| Symbol | ZX |
|---|---|
| Unit | - |
| Attribute-ID | iso_6336_method_size_factor_flank |
| Numeric ID | 16932 |
| Value Type | PMString |
The size factor ZX (flank) considers the following influences on the pitting resistance:
Note: ISO 6336 sets the size factor ZX to 1.0 (see ISO 6336:2006 part 2 section 14).
The calculation of ZX acc. to FVA 410 II has been verified for the following validity range: 0.45 mm <= mn <= 20.0 mm
For more information, see FVA research projects FVA 410 II (in German) & FVA 410 III (in German)