Profile modification

Symbol -
Unit -
Attribute-ID iso_6336_22_profile_modfication
Numeric ID 17989
Value Type PMString

The specification of the profile modification influences the determination of the load sharing factor XΓ. This is directly included in the calculation of the local flash temperature Θfl over the line of action.

The following options are available:

  1. No profile modification

  2. Adequate profile modification on the addendum of the pinion and/or the dedendum of the wheel

  3. Adequate profile modification on the addendum of the wheel and/or the dedendum of the pinion

  4. Profile modification

(ISO6336-20:2022 clause 9 formula 38-71)