Slip layer thickness

Symbol ρ'
Unit mm
Attribute-ID sliding film thickness
Numeric ID 748
Value Type PMTechValue

The slip layer thickness ρ´ is used for the calculation of the relative dynamic sensitivity factor YδrelTd. It is either determined acc. to Table 4 in ISO 6336 Part 3 based on the material, or it can be specified.