| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | supporting_factor_hub_combo |
| Numeric ID | 9020 |
| Value Type | PMString |
Supporting and hardness influence factors for different materials according to DIN 6892:
By default, the smallest factor specified in DIN is used for each material. The value can be manually overwritten and can also be outside the standard range.
| Component | Material | fS | fH |
| Feather key | Structural steel acc. to DIN EN 10025 | 1.1 - 1.4 | 1.0 |
| Bright steel acc. to DIN EN 10277-5 | 1.1 - 1.4 | 1.0 | |
| Quenched and tempered steel acc. to DIN EN 10083-1 and DIN EN 10083-2 | 1.1 - 1.4 | 1.0 | |
| Case-hardened steel acc. to DIN EN 10084 | 1.1 - 1.4 | 1.15 | |
| Shaft | Structural steel acc. to DIN EN 10025 | 1.3 - 1.7 | 1.0 |
| Quenched and tempered steel acc. to DIN EN 10083-1 and DIN EN 10083-2 | 1.3 - 1.7 | 1.0 | |
| Case-hardened steel acc. to 17210 | 1.3 - 1.7 | 1.15 | |
| Gray cast iron with graphite flakes acc. to DIN EN 1563 | 1.3 - 1.7 | 1.0 | |
| Cast steel acc. to DIN 1681 | 1.3 - 1.7 | 1.0 | |
| Gray cast iron with graphite flakes acc. to DIN EN 1561 | 1.1 - 1.4 | - | |
| Hub | Structural steel acc. to DIN EN 10025 | 1.5 | 1.0 |
| Quenched and tempered steel acc. to DIN EN 10083-1 and DIN EN 10083-2 | 1.5 | 1.0 | |
| Case-hardened steel acc. to 17210 | 1.5 | 1.15 | |
| Gray cast iron with graphite flakes acc. to DIN EN 1563 | 1.5 | 1.0 | |
| Cast steel acc. to DIN 1681 | 1.5 | 1.0 | |
| Gray cast iron with graphite flakes acc. to DIN EN 1561 | 2.0 | - |