| Symbol | ϑ0 |
|---|---|
| Unit | °C |
| Attribute-ID | vdi_2736_2014_ambient_temperature |
| Numeric ID | 9958 |
| Value Type | PMTechValue |
The following options are available:
Direct specification, exclusively for the calculation according to VDI 2736 (2014)
The oil temperature of the gear unit is used for the calculation.
The ambient temperature is used for the determining the tooth root temperature θFuß and tooth flank temperature θFla, as well as σFlimN and σHlimN (when "acc. to VDI 2736:2014" is selected).
Source: VDI 2726 (2014), Section 3.2.1