| Symbol | ϑFla,Entwurf |
|---|---|
| Unit | °C |
| Attribute-ID | vdi_2736_2014_initial_design_design_flank_temperature |
| Numeric ID | 10676 |
| Value Type | PMTechValue |
The following options are available:
The tooth flank temperature is required if "acc. to VDI 2736:2014" is selected for the rolling contact fatigue strength σHlimN. In this case, the value for σHlimN is determined based on the material designation and the curves found in VDI 2736:2014.
The tooth flank temperature is also required if measurement data is specified for the rolling contact fatigue strength σHlimN, the modulus of elasticity E, or Poisson's ratio ν.