Design tooth flank temperature

Symbol ϑFla,Entwurf
Unit °C
Attribute-ID vdi_2736_2014_initial_design_design_flank_temperature
Numeric ID 10676
Value Type PMTechValue

The following options are available:

The tooth flank temperature is required if "acc. to VDI 2736:2014" is selected for the rolling contact fatigue strength σHlimN. In this case, the value for σHlimN is determined based on the material designation and the curves found in VDI 2736:2014.

The tooth flank temperature is also required if measurement data is specified for the rolling contact fatigue strength σHlimN, the modulus of elasticity E, or Poisson's ratio ν.