Conversion factor for running and pulsator tests

Symbol fP
Unit --
Attribute-ID becal_root_conversion_factor_pulsator_to_running_test
Numeric ID 201118
Value Type PMTechValue

The tooth root strengths from running and pulsator tests can be correlated using the conversion factor. This factor summarizes the differences between the two types of test, which cover the areas of load speed, stress ratio, load progression, load sharing and distribution, as well as gearing errors. [FVA 223/xxvi]