| Symbol | YX |
|---|---|
| Unit | - |
| Attribute-ID | size factor y_x |
| Numeric ID | 750 |
| Value Type | PMDouble |
The size factor YX takes into account
DIN3990 part 3 sets the size factor YX to 1.0 (all materials for static strength)
Recent research has shown that it can even lead to an increase in the load carrying capacity of small transmissions. (see THEMIS - FVA Forschungsvorhaben 410 IIFVA 410 III (German))