If the internal S-N curve calculation is enabled, the following additional specifications are available:
- With "Extended pitting load capacity to 1010 load cycles," the S-N curve can be extended up to 1010 load cycles in the pitting load capacity calculation according to ISO 10300-2. In this case, the factor ZNT decreases to a value of ZNT = 0.85 in the fatigue area.
- With "Limited pitting permitted," some pitting can be tolerated.
(both according to ISO 10300-2:2014, page 27, table 4).