Running-in factor

Symbol XE
Unit -
Attribute-ID iso_10300_20_running_in_factor
Numeric ID 200776
Value Type PMDouble

For run-in surfaces, the running-in factor XE = 1.0.

For non run-in surfaces, the running-in factor XE is calculated from the roughness and the local equivalent radius of curvature vertical to the contact line at point C.