The local Hertzian contact stress pdyn is used to calculate the local flash temperature θfl and local specific lubricant film thickness λGF.
The following options are available:
- Acc. to Method A
The local Hertzian contact stress, pdyn,A according to Method A should be determined by a 3D mesh contact and load distribution analysis procedure. The local nominal Hertzian contact stress determined from this contact analysis pH,A is used to obtain the local Hertzian contact stress pdyn,A.
If the influence of the application factor KA and dynamic factor Kv have already been considered in the 3D load distribution, they should be set to 1.0.
The calculation according to method A can be performed in the overall system.
- Acc. to Method B
Here, the local Hertzian contact stress is determined from the nominal Hertzian contact stress. All force factors of the flank are considered.