When activated, parameters for local damage accumulation become visible and can be configured accordingly:
- A damage accumulation is performed for each stage according to the specified linear damage accumulation hypothesis. The damage accumulation can then be performed based on the locally calculated or a specified Woehler S-N curve (for input of the S-N curve, see "Local load capacity").
- The maximum permissible damage sums for the tooth flank and root are used to calculate the service life with regard to pitting and tooth root breakage.
- In the case of a single stage calculation, the load spectrum to be used must be specified here.