Load factors from DIN/ISO

Symbol -
Unit -
Attribute-ID abs_load_factor_acc_din
Numeric ID 5352
Value Type PMBoolean

Force factors (e.g.; Kv, K and K) from previous DIN/ISO calculations can be used by activating this switch.

If this is selected, the type of calculation for the force factors must be defined in the ISO 6336 tab. For example, the face load factor K cannot be determined according to "Method B (determined in system calculation)," as only individual component calculations are performed in ABS 2019.