| Symbol | hpr0*max |
|---|---|
| Unit | - |
| Attribute-ID | stplus_configuration_maximum_protuberance_height_factor_tool |
| Numeric ID | 9482 |
| Value Type | PMDouble |
The max. protuberance is acquired using the maximum tool protuberance height factor hpr0*max = hpr0 / (haP0 + hFf0). The default value is 0.75; it can be set between 0 and 1.
For more information, see STplus documentation (in German)