Calculation of local load carrying capacity

Symbol -
Unit -
Attribute-ID gta_switch_bevel_mesh_local_capacity
Numeric ID 12091
Value Type PMBoolean

The calculation is based on FVA Research Project 223 and additional follow-up projects.

Calculation of the local load capacity for all bevel gear and hypoid stages.

The calculation is performed using the FVA program BECAL (in German), based on the results of the local stress calculation.

If operating conditions such as oil and material information, roughness, temperatures, and lubricating conditions are specified, many local load capacity checks can be performed. This results in the safety values for certain gear damage and required intermediate values:

Local load capacity