Plain bearing calculation (without iteration)

Symbol -
Unit -
Attribute-ID gta_switch_slide_bearing_with_linear_stiffness
Numeric ID 14298
Value Type PMBoolean

If this switch is activated, axial and radial plain bearings are only considered as linear stiffnesses in the system calculation. Following the system calculation, a plain bearing simulation is then performed for each bearing with the loads determined from the system.

This makes it possible to make initial statements about the behavior of the plain bearings in the gear unit with significantly shorter calculation times.