| Symbol | ZX |
|---|---|
| Unit | - |
| Attribute-ID | iso_6336_method_size_factor_flank |
| Numeric ID | 16932 |
| Value Type | PMString |
The size factor ZX (flank) takes the following into consideration:
on the pitting resistance.
Note: ISO 6336 sets the size factor ZX to 1.0 (see ISO 6336:2006 part 2 section 14) (see THEMIS - FVA Forschungsvorhaben 410 II (in German) & FVA 410 III (in German)
The calculation of ZX acc. to FVA 410 II.
The calculation approach has been verified for the following validity ranges:
0.45 mm <= mn <= 20.0 mm