Root endurance limit

Symbol σFlim
Unit N/mm²
Attribute-ID nominal_endurance_limit_for_bending_stress
Numeric ID 2927
Value Type PMTechValue

Increased strength by shot-peening

ISO 6336-5:2003 lists the following increases to the safety against tooth root fracture for case-hardened gears:

(see ISO 6336-5:2003, Section 6.7)

In order to include the increased load carrying capacity in the calculation, σFE and σFlim should be increased accordingly.