K_TAUZUL material factor

Symbol -
Unit -
Attribute-ID fva 888 material factor k_tauzul
Numeric ID 5823
Value Type PMDouble

The factor Ktzul, which describes the linear relationship between local hardness and local permissible shear strength, has been set to 0.4 based on available test results and extensive experience from practical application, and includes a calibration for case-hardened gears with standard material and structural properties [1]. Using a calibrated value of 0.4 for Ktzul shows a very good correlation between experimental test results as well as experience from practical application with corresponding calculation results [1]. [

1] Witzig J.: Flank Breakage - A Limitation of the Gear Load Capacity Beyond the Material Depth. Dissertation TU Munich 2012.