| Symbol | pdyn |
|---|---|
| Unit | - |
| Attribute-ID | stplus_switch_iso_tr_15144_p_dyn_combo |
| Numeric ID | 10301 |
| Value Type | PMString |
The following methods are available for the determination of the local Hertzian contact stress:
Method A
Here, the local Hertzian contact stress is determined in advance using a 3D load distribution analysis procedure and specified for the ISO TR 15144 standard calculation.
The values determined in this way are generally modified with the application factor KA and the dynamic factor Kv. If the influence of the application and dynamic factors have already been taken into account in the 3D load distribution calculation, KA and Kv should be set to 1.0.
The calculation according to method A can be performed in the overall system.
Method B
Here, the local Hertzian contact stress is determined from the nominal Hertzian contact press. All force factors of the flank are taken into account.