Bulk temperature

Symbol θM
Unit °C
Attribute-ID iso_6336_22_bulk_temperature
Numeric ID 4718
Value Type PMTechValue

The bulk temperature θM is the temperature of the tooth surface immediately before the engagement. It is set according to the thermal balance in the gear unit casing.

The following options are available:

  1. User input
    Direct numerical input

  2. Acc. to ISO 6336 part 22