Calculation process

Symbol -
Unit -
Attribute-ID berechnungsgang
Numeric ID 1899
Value Type PMInteger

The following calculation processes are available to determine the transferable torque, axial force, and the safeties of the tapered interference fit.

Calculation process Kernel-specific output
Specification of the fitting distance Max. / Min. Joint pressure, option for calculation of a multi-stage connection
Specification of the utilization Fitting distance
Specification of the torque / axial force Fitting distance, required joint pressure, useful for shaft calculation

If the tapered interference fit calculation is performed as part of the shaft calculation, only the "torque / axial force specified" calculation process is appropriate. The torque from the stage and the axial force from the shaft are used.