| Symbol | ZXY |
|---|---|
| Unit | - |
| Attribute-ID | calculation_point_virtual_cylindrical_gear_pair_fva_411 |
| Numeric ID | 11466 |
| Value Type | PMInteger |
The calculation point on the path of contact of the virtual cylindrical gear (the points A, B, C, M (centre point), D or E) can be selected to determine the pitting load capacity. The standard method is the original calculation method according to FVA 411 (calculation point M-B) for determining the pitting load capacity.