| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | agma_925_a03_number_of_calculation_points_along_the_line_of_action |
| Numeric ID | 12963 |
| Value Type | PMInteger |
AGMA 925-A03 calculations are generally performed for points A-E. Additional intermediate points for the calculation can be defined here. The number of points selected is evenly distributed across the entire line of action.
The value specified here is used exclusively for calculation according to AGMA 925-A03. All calculations which refer to a point on the line of action (i.e. calculation of the flash temperature) are performed for each of these points.
Source: AGMA 925-A03, Section 4.1.4 et seq.