Axial distance between load introduction and discharge points

Symbol a0
Unit mm
Attribute-ID axial_distance_load_a0
Numeric ID 3975
Value Type PMTechValue

Axial distance between load input and output points within the power flow. The value must be greater than 0 and less than or equal to the supporting length of the feather key.

a0 Axial distance between load input and output points
a1 Distance between hub face and load-bearing part of the feather key
bN Total width of the hub
c Width of the hub with diameter D2 within the supporting length
d Shaft diameter
uK Position
lPF Length of the feather key
ltr Supporting length of the feather key
D1 Small outer diameter of stepped hub
D2 Large outer diameter of stepped hub
BND1 Width of the hub for D1
BND2 Width of the hub for D2
Fu Circumferential force
T Torsional moment
- - - Part of the feather key connection in the power flow