| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | stplus_configuration_switch_notification_tip_clearance |
| Numeric ID | 9499 |
| Value Type | PMDouble |
The default value for minimum tip clearance cmin relative to mn is 0.13. It can be set from 0.001 to 0.99. If the tip clearance factor c* is specified in the geometry data, it is only used if it is less than the maximum tip clearance cmax relative to mn (default value = 0.75). cmax can vary between 0.00001 and 1.0.
A notification for low tip clearance is issued if the actual tip clearance relative to mn is less than 0.2. The value can vary between 0.05 and 0.5.
For more information, see STplus documentation (in German)