Determination of the local Hertzian contact stress

Symbol pdyn
Unit -
Attribute-ID iso_6336_22_local_hertzian_contact_stress_combo
Numeric ID 10301
Value Type PMString

The local Hertzian contact stress pdyn will be used to calculate the local flash temperature θfl and local specific lubricant film thickness λGF.

The following options are available:

  1. Acc. to Method A
    The local Hertzian contact stress, pdyn,A according to Method A should be determined by a 3D mesh contact and load distribution analysis procedure. The local nominal Hertzian contact stress determined from this contact analysis pH,A will be used to obtain the local Hertzian contact stress pdyn,A.
    pdyn,Y,A=pH,Y,A·KA·Kv

    If the influence of the application factor KA and dynamicfactor Kv have already been taken into account in the 3D load distribution they should be set to 1.0.

    The calculation according to method A can be performed in the overall system.

  2. Acc. to Method B
    Here, the local Hertzian contact stress is determined from the nominal Hertzian contact stress. All force factors of the flank are taken into account.

    pdyn,Y,B=pH,Y,B·KA·Kγ·Kv·KHα·KHβpH,Y,B=ZE·Ft·XYb·ρn,Y·cosαtZE=Er2π