Temperature factor

Symbol Yθ
Unit -
Attribute-ID agma2101c95 temperature factor Y_theta
Numeric ID 1118
Value Type PMDouble

The value 1 is assumed for the temperature factor in the range from 0°C - 120°C for gear bodies or oil temperature.

When the operating temperature leads the gear body temperature to fall under 0°C, the following should be noted for the materials used:

A value greater than 1 is assumed for the temperature factor for operating temperatures over 120°C.

At temperatures over 150°C, the hardness and strength losses of the materials used must be taken into consideration.