Sliding safety (combined loads)

Symbol SR
Unit -
Attribute-ID sliding_safety
Numeric ID 19334
Value Type PMDouble

From the validity of Coulomb's law of friction in the joint, an ellipsoidal relationship for the transmission range of the interference fit connection results for combined loads (cf. among others Final Report FVA 312-I Section 6.5). The combined sliding safety of a tapered interference fit is given by

or

The term with the bending moment is omitted for cylindrical interference fit connections.