Minimum permissible bottom clearance

Symbol cmin
Unit -
Attribute-ID stplus_configuration_minimum_tip_clearance
Numeric ID 9497
Value Type PMDouble

The default value for minimum tip clearance cmin relative to mn is 0.13. It can be set from 0.001 to 0.99. If the tip clearance factor c* was specified for the "geometry data", it is only accepted if it is smaller than the maximum tip clearance cmax (default = 0.75) related to mn. cmax can vary between 0.00001 and 1.0.

A notification for low tip clearance is issued if the actual tip clearance relative to mn is less than 0.2. The value can vary between 0.05 and 0.5.