Load sharing factor

Symbol Kγ
Unit -
Attribute-ID force distribution factor
Numeric ID 1036
Value Type PMDouble

In planetary stages, the load can be distributed differently over the individual planetary meshes. This can be considered in the FVA-Workbench as follows:

Calculation of the torque distribution in the mechanical system
The load distribution to the planets is determined based on the gearbox stiffnesses, gravity, specified offsets of the planetary pins, and any transverse forces acting in the planetary stage. In this case, the load sharing factor Kγ cannot be manually specified. The load capacity is determined using a combination of the highest calculated torque and the worst face load factor KHß from all engagements, and, as recommended in ISO 6336, a load sharing factor of Kγ =1.0. The resulting load distribution factor compared to the nominal torques is output for information purposes.

Specification of the load sharing factor
If the system calculation is configured to use the nominal torques for the load capacity calculations, the load sharing factor Kγ can (and must) be manually specified. In this case, the nominal torques in the planetary meshes are multiplied by this factor for the load capacity calculations.