Load capacity acc. to ISO 10300 (2014) in load spectrum

Symbol -
Unit -
Attribute-ID gta_switch_bevel_mesh_din_3991_spectrum
Numeric ID 14300
Value Type PMBoolean

Activates calculation of the load capacity according to ISO 10300 (2014).

The calculation is based on FVA Research Project 49 and additional follow-up projects.

Additional calculation methods can be activated in the "ISO 10300 / DIN 3991 & additional calculations" tabs under the bevel gear stage.